Download Submission Response
You can download the results using the MSATS Web Portal or downloadFile API endpoint.
Download BUT submission response
Participants can only access submissions for their own Participant ID.
- Access the Blind Updates web interface.
- In the Blind updates interface, find the submission response to download.
- In the Action column, click Download and save the file to your local folders.
-
BUT submission response format
For field details, see Create the payload.
The response content is in AEMO’s CSV Data Format Standard and contains the submission payload with the following changes.
|
Column |
Change from submission |
|---|---|
|
C |
The BLIND_UPDATE_SUBMISSION (BUS) is changed to BLIND_UPDATE_RESPONSE (BUR) |
|
D |
From (reversed) |
|
E |
To (reversed) |
|
F |
Publish date (updated) |
|
G |
Publish time (updated) |
|
L |
Payload ID populated with the same value provided by the Initiator in the C row (L column) of the Submission. |
|
M |
Response Payload ID has the AEMO-generated unique identifier provided as a reference in the BUT Submission Message acknowledgement and the BUT Response |
BUT submission response details
|
Column |
C row |
I row |
D row |
|---|---|---|---|
|
A |
C |
I |
D |
|
B |
System |
BUR |
BUR |
|
C |
NMI See Relevant Rules or Procedures_DATA METER_REGISTER REGISTER_IDENTIFIER |
NMI_DATA METER_REGISTER REGISTER_IDENTIFIER |
|
|
D |
NEMMCO |
1 |
1 |
|
E |
PARTICIPANT ID |
NMI |
DATA |
|
F |
Publish date |
FIELD |
DATA |
|
G |
Publish time |
VALUE |
DATA |
|
H |
Empty |
RESPONSE_CODE |
|
|
I |
Empty |
RESPONSE_DESCRIPTION |
Success/fail |
|
J |
Empty |
|
|
|
K |
Market |
|
|
|
L |
Payload ID |
|
|
|
M |
Response Payload ID |
|
|
BUT submission response examples
For details about response codes and descriptions, see Validation
Example 1
C,DEV,BLIND_UPDATE_TOOL,NEMMCO,UMPLP,2022/06/15,13:25:39,,,,NEM,Participant Test Msg ID,100000000000008
I,BUR,NMI_DATA,1,NMI,FIELD,NEW_VALUE,STATUS,RESPONSE_CODE,RESPONSE_DESCRIPTION,OLD_VALUE,UPDATED_ROW_ID,BUT Blind Update Tool_UPDATE_TS
D,BUR,NMI_DATA,1,2001000734,SHARED_ISOLATION_POINT_FLAG,I,UPDATED,0,Success,,64860681,2022/06/15 13:25:39
D,BUR,NMI_DATA,1,2001003565,SHARED_ISOLATION_POINT_FLAG,N,ERROR,24,This value is not a known code. Code collection : SHARED_ISOLATION_POINT_FLAG,,,
D,BUR,NMI_DATA,1,2001005350,SHARED_ISOLATION_POINT_FLAG,U,ERROR,24,This value is not a known code. Code collection : SHARED_ISOLATION_POINT_FLAG,,,
D,BUR,NMI_DATA,1,2001003743,SHARED_ISOLATION_POINT_FLAG,Y,ERROR,24,This value is not a known code. Code collection : SHARED_ISOLATION_POINT_FLAG,,,
C,END OF REPORT,7
Example 2
C,DEV,BLIND_UPDATE_TOOL,NEMMCO,CNRGYP,2022/05/09,13:02:19,,,,NEM,Participant Test Msg ID,100000000000146
I,BUR,NMI_DATA,1,FIELD,NMI,NEW_VALUE,STATUS,RETURN_CODE,RETURN_MESSAGE,OLD_VALUE,UPDATED_ROW_ID,BUT_UPDATE_TS
I,BUR,METER_REGISTER,1,FIELD,NMI,METER_SERIAL,NEW_VALUE,STATUS,RETURN_CODE,RETURN_MESSAGE,OLD_VALUE,UPDATED_ROW_ID,BUT_UPDATE_TS
I,BUR,REGISTER_IDENTIFIER,1,FIELD,NMI,METER_SERIAL,REGISTER_ID,NEW_VALUE,STATUS,RETURN_CODE,RETURN_MESSAGE,OLD_VALUE,UPDATED_ROW_ID,BUT_UPDATE_TS
D,BUR,NMI_DATA,1,SHARED_ISOLATION_POINT_FLAG,4001002235,U,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,SHARED_ISOLATION_POINT_FLAG,4001002273,U,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,SHARED_ISOLATION_POINT_FLAG,4001002275,U,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,DP_NUMBER,4001002235,a DP number,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,DP_NUMBER,4001002273,a DP number,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,DP_NUMBER,4001002275,a DP number,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,SECTION_NUMBER,4001002235,a section number,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,SECTION_NUMBER,4001002273,a section number,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,SECTION_NUMBER,4001002275,a section number,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,CONNECTION_CONFIGURATION,4001002235,AB,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,CONNECTION_CONFIGURATION,4001002273,AB,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,NMI_DATA,1,CONNECTION_CONFIGURATION,4001002275,AB,ERROR,14,This field has been updated by a prior BUT run,,,
D,BUR,METER_REGISTER,1,NEXT_SCHEDULED_READ_DATE,4001016072,45,2022/07/03,ERROR,25,CNRGYP is not privileged to update this Table/Record/Field at this time,,,
D,BUR,METER_REGISTER,1,NEXT_SCHEDULED_READ_DATE,4001008826,45021,2022/07/03,ERROR,25,CNRGYP is not privileged to update this Table/Record/Field at this time,,,
D,BUR,METER_REGISTER,1,NEXT_SCHEDULED_READ_DATE,4001015617,45179,2022/07/03,ERROR,25,CNRGYP is not privileged to update this Table/Record/Field at this time,,,
D,BUR,REGISTER_IDENTIFIER,1,NT_INFO,4001004107,53824,1,R feed,ERROR,12,Table/Column is not valid for processing at this time,,,
D,BUR,REGISTER_IDENTIFIER,1,NT_INFO,4001004131,119402,1,R feed,ERROR,12,Table/Column is not valid for processing at this time,,,
D,BUR,REGISTER_IDENTIFIER,1,NT_INFO,4001004107,53826,1,R feed,ERROR,12,Table/Column is not valid for processing at this time,,,
D,BUR,REGISTER_IDENTIFIER,1,DIAL_FORMAT,4001004107,53824,1,70.21,ERROR,27,Old value (5) was not null,5,82005323,
D,BUR,REGISTER_IDENTIFIER,1,DIAL_FORMAT,4001004131,119402,1,70.21,ERROR,27,Old value (5) was not null,5,80192107,
D,BUR,REGISTER_IDENTIFIER,1,DIAL_FORMAT,4001004107,53826,1,70.21,ERROR,27,Old value (5) was not null,5,81364232,
C,END OF REPORT,26