Participant Categories, Unit States, and Recall Times
Mandatory if Available Recall Times are only mandatory where recall information applies. NULL submissions are valid if recall is not possible.
The following table describes the registered participant categories, unit states, and recall times fields for MT PASA Medium Term Projected Assessment of System Adequacy. A 24-month supply demand forecast, published weekly, with daily resolution. Offers.
Registered participant category |
DUID connection type |
Unit state |
Unit state type |
Outage type |
Recall time |
Weekly energy limit |
PASA availability |
---|---|---|---|---|---|---|---|
Scheduled Generator |
SGU |
Inactive reserve (InactiveReserve) |
Deactivated Shutdown |
Economic |
Mandatory |
null or >= 0 |
0 |
SGU |
Mothballed (Mothballed) |
Deactivated Shutdown |
Economic |
Mandatory |
null or >= 0 |
0 |
|
SGU |
Retired |
Deactivated Shutdown |
Economic |
None |
null or >= 0 |
0 |
|
SGU |
No deratings (NoDeratings) |
Available |
When submitted MT PASA Availability is dependable capacity not just maximum capacity, also includes seasonal derating |
None |
null or >= 0 |
>0 |
|
SGU |
Basic planned deratings (DeratingPlanBasics) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
SGU |
Derating plan extend (DeratingPlanExtend) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
SGU |
Unplanned forced deratings (DeratingUnplanForced) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
SGU |
Unplanned maintenance deratings (DeratingUnplainMaint) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
SGU |
Basic planned outage (OutagePlanBasic) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
SGU |
Extended planned outage (OutagePlanExtend) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
SGU |
Unplanned forced outage (OutageUnplanForced) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
SGU |
Unplanned maintenance outage (OtageUnplanMaint) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
Integrated Resource Provider |
BDU SGU |
Inactive reserve (InactiveReserve) |
Deactivated Shutdown |
Economic |
Mandatory |
null or >= 0 |
0 |
BDU SGU |
Mothballed (Mothballed) |
Deactivated Shutdown |
Economic |
Mandatory |
null or >= 0 |
0 |
|
BDU SGU |
Retired (Retired) |
Deactivated Shutdown |
Economic |
None |
null or >= 0 |
0 |
|
BDU SGU |
No deratings (NoDeratings) |
Available |
When submitted MT PASA Availability is dependable capacity not just maximum capacity, also includes seasonal derating |
None |
null or >= 0 |
>0 |
|
BDU SGU |
Basic planned deratings (DeratingsPlanBasic) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
BDU SGU |
Derating plan extend (DeratingPlanExtend) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
BDU SGU |
Unplanned forced deratings (DeratingUnplanForced) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
BDU SGU |
Unplanned maintenance deratings (DeratingUnplanMaint) |
Available |
Physical |
Optional |
null or >= 0 |
>0 |
|
BDU SGU |
Basic planned outage (OutagePlanBasic) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
BDU SGU |
Extended planned outage (OutagePlanExtend) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
BDU SGU |
Unplanned forced outage (OutageUnplanForced) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
BDU SGU |
Unplanned maintenance outage (OutageUnplanMaint) |
Unavailable |
Physical |
Optional |
null or >= 0 |
0 |
|
Market Customer |
SLU |
– |
– |
– |
Optional |
null or >= 0 |
>=0 |
Market Network Service Provider |
SNS |
– |
– |
– |
Optional |
Null |
>=0 |
Integrated Resource Provider |
SLU |
– |
– |
– |
Optional |
null or >= 0 |
>=0 |
For Production Units, unit state is mandatory and cannot be NULL.
The IESS changes will become effective on 2 June 2024.