INT177 - ESV injection withdrawal report
Trigger type |
Event triggered |
Published |
Issue of Final Settlements |
Audience |
Market participants |
Output file name |
int177_v[n]_esv_injection_withdrawal_[p]~yyyymmddhhmmss.csv |
Report purpose
The Gas Safety Act 1997 section 29 outlines that gas companies are required to pay the Energy The unit must be a generator for the service type: ‘energy’. Loads cannot bid for mandatory restrictions capacity. Safe Victoria (ESV) a levy, over a schedule period. "Determination by Minister of for Energy Industries and Resources", Under Section 29 of the Gas Safety Act 1997, For the year 1 July 2004 to 30 June 2006. In relation to the Levy to Apply to Gas Companies. The report provides the injections and end-use withdrawals from the Gas Transmission System i.e DTS Declared Transmission System (Victoria). Victoria’s gas transmission system, operated by AEMO. and Non-DTS for Market participant, as defined under the Gas Industry Act by the gas retailers.Report A data report that loads into a data model table. Identified by its type, subtype, and version. For example: BILLING,BILLINGASPAYMENTS,2 will include billing mirn i.e DM and logical mirns
Audience notes
Participants specific data provided to the Energy Safe Victoria (ESV) in INT119 can be seen in this report.
Content notes
Data content
Name |
Data Type |
No Nulls |
Primary Key |
CQ |
Comments |
---|---|---|---|---|---|
statement_version_id |
integer |
True |
True |
N |
Unique settlement statement number |
Month |
varchar(8) |
True |
True |
N |
Derived from a gas date (currently 6:00 AM to 6:00 AM) not calendar date. Displayed as MMM-YYYY e.g. Aug-2009 |
network_name |
varchar(40) |
True |
True |
Description of the particular DTS/Non DTS Network |
|
settlement_cat_type |
varchar(3) |
True |
False |
Settlement Type e.g. FNL (Final), REV(Revision), NA for Non DTS |
|
company_id |
integer |
True |
False |
company id of individual organisation |
|
Mirn |
varchar(10) |
True |
False |
N |
Meter number |
injection_withdrawal |
char(1) |
True |
False |
I for Injections/ W for Withdrawal |
|
total_energy_gj |
numeric(18,3) |
True |
False |
N |
Total injections for individual organisation OR Withdrawals for individual organisation |
current_date |
datetime |
True |
False |